ABB PC SDK Adapter
Backup and restore ABB IRC5 robot controllers running RobotWare 5, using the ABB PC SDK.
What This Adapter Does
This adapter connects to an ABB IRC5 robot controller running RobotWare 5 over the network using the ABB PC SDK and triggers a controller backup or restore. Connecting to RobotWare 5 controllers requires an ABB PC SDK runtime (RobotStudio, ABB PC SDK, or the ABB Robot Communication Runtime) to be installed on the host — see Requirements.
| Operation | Purpose |
|---|---|
| ABB IRC5 RW5 Backup | Trigger a controller backup to a path on the controller |
| ABB IRC5 RW5 Restore | Restore a controller from a backup path on the controller |
The adapter discovers the controller on the local network and connects to it; it requires the controller's network discovery ports to be reachable.
flowchart LR
A[OT Backup Job] --> B{Operation}
B --> C[ABB IRC5 RW5 Backup]
B --> D[ABB IRC5 RW5 Restore]
C --> E[IRC5 Controller via PC SDK]
D --> E
Compatibility
| Software / Device | Supported versions | Notes |
|---|---|---|
| ABB robot controller | IRC5 | Robot controller hardware |
| RobotWare | 5 | Controller firmware family |
| ABB PC SDK runtime | RobotStudio, ABB PC SDK, or Robot Communication Runtime | Must be installed on the host — see Requirements |
| .NET runtime | .NET 8 + ASP.NET Core 8 | Required on the host |
Job Configuration
The sections below describe the parameters you fill in when creating or editing a backup or restore job for each operation.
ABB IRC5 RW5 Backup
Connects to the controller, authenticates, and triggers a backup to the specified path on the controller. Waits up to 240 seconds for the backup to complete.
| Parameter | Description | Example |
|---|---|---|
| ControllerIp | The network address of the controller to backup. | 192.168.1.10 |
| ControllerAccount | The controller credentials used to authenticate. Select an Account configured in OT Backup. | (Account) |
| ControllerBackupPath | The path where the backup will be stored on the controller. | $BACKUP/MyRobot |
ABB IRC5 RW5 Restore
Connects to the controller, authenticates, and triggers a restore from the specified backup path on the controller. The controller must be in Auto mode. Waits up to 240 seconds for the controller to come back online.
| Parameter | Description | Example |
|---|---|---|
| ControllerIp | The network address of the controller to restore. | 192.168.1.10 |
| ControllerAccount | The controller credentials used to authenticate. Select an Account configured in OT Backup. | (Account) |
| ControllerBackupPath | The path on the controller of the backup to restore. | $BACKUP/MyRobot |
Requirements
Host machine
ABB PC SDK runtime — for RobotWare 5 (IRC5) robots the host must have one of the following installed:
- RobotStudio, or
- ABB PC SDK, or
- ABB Robot Communication Runtime
Download the PC SDK / Robot Communication Runtime from the ABB PC SDK download page, or use the installation file bundled in the
…\OT Backup\TEE\_SDKfolder.The OT Backup host must be able to discover and reach the controller on the local network.
Network / Ports
| Protocol | Port | Direction | Purpose |
|---|---|---|---|
| UDP | 5512–5514 | Outbound | Controller discovery (ABB network scanning) |
| TCP | 5515 | Outbound | PC SDK communication with the controller |
Permissions / Access
- An Account with controller credentials that have permission to perform backup and restore must be configured in OT Backup and selected in the step.
Setup
These steps must be completed by an IT administrator and the robot owner.
- Place the OT Backup host where it can reach the controller — the PC SDK uses ABB network discovery, so the host must be able to discover the controller on the network.
- Install the ABB PC SDK runtime — install RobotStudio, the ABB PC SDK, or the ABB Robot Communication Runtime on the host. Use the ABB PC SDK download page or the installer in
…\OT Backup\TEE\_SDK. - Verify connectivity — confirm the host can reach the controller and that UDP 5512–5514 and TCP 5515 are open through any firewalls between the host and the robot network.
- Configure an Account — add the controller credentials as an Account in OT Backup and reference it in the step.
Troubleshooting
| Symptom | Likely cause | Resolution |
|---|---|---|
| "Failed to connect to controller" | Controller not discoverable | Verify the IP, ensure the host can reach the controller, and open UDP 5512–5514 / TCP 5515 |
| Step fails immediately / "PC SDK not found" | ABB PC SDK runtime not installed on the host | Install RobotStudio, the ABB PC SDK, or the ABB Robot Communication Runtime (see Requirements) |
| "Controller is not available" | Controller busy or in use by another client | Wait until the controller is available and retry |
| Restore fails — "must be in Auto" | Controller not in Auto mode | Set the controller to Auto mode before running the restore |
| Backup or restore times out after 240 seconds | Controller slow or unreachable | Check the network path to the controller and retry |
Known Limits
- Restore requires the controller to be in Auto mode and takes mastership during the operation.
- Backup and restore each wait up to 240 seconds to complete.
- The controller must be discoverable on the local network (ABB network discovery is used to locate it).
See Also
- ABB RWS1 Adapter — IRC5 controllers running RobotWare 6
- ABB RWS2 Adapter — OmniCore controllers running RobotWare 7